Protect your electrical system efficiently with the Schneider Acti9 iC60 RCBO, designed to provide superior protection against earth leakage with a 20 A rating and 30 mA sensitivity, ensuring safety for people and equipment.

Specifications

  • Brand: Schneider
  • Product Type: Acti9 iC60 Residual Current Circuit Breaker
  • Model Number: RCBO A9D11820
  • Current Rating: 20 A
  • Breaking Capacity: 10 kA
  • Earth Leakage Sensitivity: 30 mA
  • Number of Poles: 1
  • Operating Temperature: -15 to +60°C
  • Mounting: Snap-on
  • Control/Tripping Technology: Magnetic-Thermal
  • Additional Detail: C Curve

Features

  • 1P+N circuit breaker with 20A rated current and C trip curve
  • Earth leakage protection type A with 30 mA sensitivity and instantaneous trip
  • Short-circuit breaking capacity up to 10,000 A per IEC 61009-2-2
  • Visitrip indicator to quickly identify faulty circuits and reduce intervention time
  • Visisafe green strip ensures physical contact opening for safe maintenance
  • Independent fast-closing mechanism enhances service life
  • Complies with AS/NZS 61009.1 and IEC 61009-1 standards
  • Electrical endurance up to 5000 cycles, mechanical endurance up to 20,000 cycles
  • Operating voltage Ue: 240 V AC, rated insulation voltage Ui: 400 V AC, impulse withstand voltage Uimp: 4 kV
  • Frequency: 50 Hz, DIN rail mountable, 18 mm width
  • Color: White (RAL9003), Dimensions: 18×110×77.5 mm, Weight: 205 g
  • Protection degree: IP20, IP40 in enclosure, Operating temp: -15 to 60°C, Storage temp: -40 to 85°C

Uses

  • Detects earth leakages and disconnects power to protect people from electric shocks
  • Protects electrical devices and equipment from damage caused by leakage currents
  • Prevents electrical accidents such as fires or equipment damage due to earth leakage

FAQ

Is this RCBO suitable for electric shock protection?

Yes, it is designed to detect earth leakages and instantly cut off power to protect people.

Does it protect electrical equipment from damage?

Yes, it prevents unwanted earth leakages that could damage devices and equipment.

Can the RCBO be used in industrial and commercial installations?

Yes, it is suitable for industrial and commercial setups to provide reliable protection against earth leakage.